Tripp Lite
Product Type:
Power distribution unit
Installation Type:
Rack-mountable
Model:
PDU 3-Phase Monitored Per-Outlet 14.4kW - LX Platform, 6 C13 & 12 C19 Outlets (208V), 50A CS8365C, 0U, TAA
Input Voltage:
AC 208 V
Power Provided:
14.4 kW
Remote Management Interface:
Ethernet 10/100, Serial, USB
View More
Out of Stock

Out of Stock.

Request a quote for re-stock information.

Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.

Hear What Our Customers Are Saying

slide 6 to 10 of 50
This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for your data center, computer room or high-density network closet, the PDU3EVNR6H50A features six C13 and 12 C19 208V outlets in six breakered load banks, which distribute AC power to rack equipment. Plug-lock insert sleeves are included to prevent equipment cables from becoming accidentally dislodged.
Not only can you remotely monitor voltage and frequency, but the PDU3EVNR6H50A also allows metering of per-phase input current, as well as output current per bank and per outlet. Banks can be individually monitored to ensure proper load balance and prevent downtime. Monitoring each outlet allows you to study power consumption trends for each connected device. This helps you detect hardware problems and network traffic bottlenecks, as well as compare power usage among various devices.
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, Telnet or SSH. Full 10/100/1000 Mbps auto-sensing enables optimal communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, FTP, DHCP and NTP.
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with �1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the PDU via PowerAlert Device Manager. If an EnviroSense2 module is connected, the LCD also displays status and environmental data, including temperature and humidity.
The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with a Hubbell 50A CS8365C 208V input connects the PDU to a compatible AC power source, generator or protected UPS.
The PDU3EVNR6H50A is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Product Description Eaton Tripp Lite Series PDU 3-Phase Monitored Per-Outlet 14.4kW - LX Platform, 6 C13 & 12 C19 Outlets (208V), 50A CS8365C, 0U, TAA - power distribution unit - 14.4 kW - TAA Compliant
Device Type Power distribution unit - rack-mountable
Cord Length 6 ft
Rack Size 0U
Weight 14.13 lbs
Input Wiring 3-phase
Input Voltage AC 208 V
Output Voltage AC 208 V
Power Capacity 14.4 kW
Input Connectors 1 x Hubbell CS8365C
Output connectors 6 x power IEC 60320 C13 - 208 V 12 A
12 x power IEC 60320 C19 - 208 V 16 A
Networking Ethernet 10/100, USB, serial
Remote Management Protocol SNMP 1, SNMP 2, Telnet, SNMP 3, HTTP, HTTPS, SSH, SMTP
TAA Compliant Yes
Dimensions (WxDxH) 2.2 in x 2.9 in x 70 in
Manufacturer Warranty 2-year warranty
Designed For P/N: PLC19BK, PLC19BL, PLC19RD
General
Device Type Power distribution unit - rack-mountable
Height (Rack Units) 0U
Cord Length 6 ft
Power Device
Input Voltage AC 208 V
Input Voltage Range AC 208 - 240 V
Frequency Provided 50/60 Hz
Input Wiring 3-phase
Input Connectors 1 x Hubbell CS8365C
Power Output Connectors Details 6 x power IEC 60320 C13 - 208 V 12 A
12 x power IEC 60320 C19 - 208 V 16 A
Output Voltage AC 208 V 50/60 Hz
Max Electric Current 50 A
Power Capacity 14.4 kW
Circuit Protection Circuit breaker
Networking
Remote Management Interface Ethernet 10/100, USB, serial
Remote Management Protocol SNMP 1, SNMP 2, Telnet, SNMP 3, HTTP, HTTPS, SSH, SMTP
Expansion / Connectivity
Interfaces 2 x USB - 4 pin USB Type A
1 x management (Fast Ethernet) - RJ-45
1 x serial - RJ-45
1 x USB - 4 pin USB Type B
Miscellaneous
Cables Included Power cable - integrated - 6 ft
Console cable - external
Rack Mounting Kit Included
Features Vertical orientation, overload protection, firmware upgradable, monitored, phase monitoring, built-in LX platform interface
Compliant Standards NOM, RoHS, UL 60950-1, FCC Part 15 A, CAN/CSA-C22.2 No. 60950-1
TAA Compliant Yes
Manufacturer Warranty
Service & Support Limited warranty - 2 years
Environmental Parameters
Min Operating Temperature 32 °F
Max Operating Temperature 122 °F
Humidity Range Operating 5 - 95% (non-condensing)
Dimensions & Weight
Width 2.2 in
Depth 2.9 in
Height 70 in
Weight 14.13 lbs
Dimensions & Weight (Shipping)
Shipping Width 6.9 in
Shipping Depth 9.6 in
Shipping Height 76 in
Shipping Weight 27.07 lbs