Tripp Lite PDU Hot-Swap 200-240V 16A Single-Phase With Manual Bypass - 5 C13 and 1 C19 Outlets, 2 C20 Inlets, 1U Rack/Wall; - Power Distribution Unit - 3.8 KW - PDUBHV201U

SKU:
PDUBHV201U
Shipping:
Calculated at Checkout
$211.54 $121.46
(You save $90.08 )

Image may not exactly match the product.

Out of Stock.

Request a quote for re-stock information.

$211.54 $121.46
(You save $90.08 )
Availability:
Currently out of stock, pre-order may be available

Condition:
New
Warranty Information
Limited Warranty - 2 years
Product Line:
Tripp Lite
Product Type:
Power distribution unit
Installation Type:
Rack-mountable
Model:
PDU Hot-Swap 200-240V 16A Single-Phase with Manual Bypass - 5 C13 and 1 C19 Outlets, 2 C20 Inlets, 1U Rack/Wall;
Input Voltage:
AC 200/208/220/230/240 V
Power Provided:
3.8 kW

Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.

Share:
  • Ideal for supporting critical IT equipment that require 24/7/365 uptime
  • Transfers connected components to utility power with no downtime during UPS maintenance
  • Dual C20 inlets support connection to separate UPS and utility input power sources
  • ECO mode saves power by shutting down controlled outlet bank in certain conditions
  • Mounts into 1U of rack space or onto wall using included mounting hardware
  • This product is covered by a 2-year limited warranty

Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200 - 240V 16A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU's bypass switch, permitting maintenance or equipment replacement with no interruption of performance.
The PDUBHV201U features two C20 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C19-to-C20 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the outlets will continue to operate without interruption.
By enabling the ECO power saving feature, you can power off a single bank of four controlled C13 outlets all at once when the devices connected to the master C13 and C19 outlets are powered off or go into a low-power consumption mode.
Use the included mounting hardware to install the PDUBHV201U's all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.