Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.
Hear What Our Customers Are Saying
-
20+ Years Experience Helping IT Heroes
Take advantage of 20+ years of expertise from a partner with available resources for large deployments, multi-site projects, and complex IT initiatives. We have the team to get the job done. -
Free Solution Design With White Glove Engineers
Solutions architects and project engineers will help you envision a successful outcome and give you personalized recommendations based on your unique needs. Free. Apply today. -
Configuration & Installation Services
Let us take care of configuring and installing your equipment so you can get back to business. Available nationwide. Apply today. -
Equipment Trade-In Program
Refreshing old hardware? Let us coordinate the recycling or destruction in an environmentally friendly and safe manner. As a bonus, working with us gives you access to specific trade-in discounts towards your network refresh. Apply today. -
Exclusive Incentives, Special Pricing, & Financing
After helping you build and validate your solution, we’ll include any applicable discounts, financing, and incentives applied to your project to guarantee you get the most value out of your IT investments through Hummingbird Networks. Apply today.
Specifications
Manufacturer: Tripp Lite
Manufacturer Part Number: PDUMH15HVATNET
Manufacturer Website Address: http://www.tripplite.com
Brand Name: Tripp Lite
Product Model: PDUMH15HVATNET
Product Name: PDUMH15HVATNET 10-Outlet PDU
Marketing Information: 2-2.4kW Single-Phase ATS PDU with Primary and Secondary Inputs for Power Redundancy
Recommended for data centers, server rooms and network closets, this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-foot (3.7-meter) input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.
Switches from Primary to Secondary Power Source in Milliseconds
Dynamic solid-state automatic transfer switching (ATS) allows the IEC C13 PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source.
Switched C13 Outlets Are Individually Controllable for Remote Reboots and Load Shedding
This switched power distribution unit distributes, monitors and manages selectable 200-240V power to equipment in network applications requiring individual outlet control, load shedding and remote monitoring of critical network components. Eight switched C13 outlets (two additional C13 outlets are unswitched) are subject to advanced network control and remote power monitoring, including the ability to turn on, turn off, reboot or lock out power to each outlet. Reducing the frequency of on-site visits can save you money and reduce downtime, thus lowering the PDU's total cost of ownership.
Check Essential Functions at a Glance
A front-panel digital load meter displays total PDU output current in amps. LEDs indicate on/off status of individual outlets and power status of primary and secondary inputs. An input-voltage select switch lets you toggle between high (220, 230 or 240V) or low (200 or 208V) voltage.
Built-In LX Platform Interface Gives You Unrestricted Remote Access to Your Equipment 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
Easy to Install Horizontally in an EIA-Standard 19 in. Rack
This ATS PDU mounts in 1U of space in 19-inch rack or rack cabinet using the included brackets and hardware.
TAA-Compliant for GSA Schedule Purchases
The PDUMH15HVATNET is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
2-Year Warranty
The PDUMH15HVATNET is backed by a 2-year warranty, ensuring reliability and performance.
Packaged Quantity: 1
Product Type: PDU
Technical Information
Input Receptacles: 2 x IEC 60320 C14
Output Receptacles: 10 x IEC 60320 C13
Protection Type: Overload Protection
Power Description
Input Voltage: 230 V AC
Input Voltage Range: 200 V AC - 240 V AC
Output Voltage:
Power Rating (Watt): 2400 W
Input Current: 10 A
Management
Management:
Interfaces/Ports
Network (RJ-45): Yes
Physical Characteristics
Mounting Orientation: Horizontal
Placement: Rack
Rack Height: 1U/2U
Height: 1.7"
Width: 17.3"
Depth: 14.4"
Weight (Approximate): 10.41 lb
Miscellaneous
Package Contents:
Environmentally Friendly: Yes
Environmental Certification: RoHS
TAA Compliant: Yes
Warranty
Limited Warranty: 2 Year
Manufacturer: Tripp Lite
Manufacturer Part Number: PDUMH15HVATNET
Manufacturer Website Address: http://www.tripplite.com
Brand Name: Tripp Lite
Product Model: PDUMH15HVATNET
Product Name: PDUMH15HVATNET 10-Outlet PDU
Marketing Information: 2-2.4kW Single-Phase ATS PDU with Primary and Secondary Inputs for Power Redundancy
Recommended for data centers, server rooms and network closets, this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-foot (3.7-meter) input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.
Switches from Primary to Secondary Power Source in Milliseconds
Dynamic solid-state automatic transfer switching (ATS) allows the IEC C13 PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source.
Switched C13 Outlets Are Individually Controllable for Remote Reboots and Load Shedding
This switched power distribution unit distributes, monitors and manages selectable 200-240V power to equipment in network applications requiring individual outlet control, load shedding and remote monitoring of critical network components. Eight switched C13 outlets (two additional C13 outlets are unswitched) are subject to advanced network control and remote power monitoring, including the ability to turn on, turn off, reboot or lock out power to each outlet. Reducing the frequency of on-site visits can save you money and reduce downtime, thus lowering the PDU's total cost of ownership.
Check Essential Functions at a Glance
A front-panel digital load meter displays total PDU output current in amps. LEDs indicate on/off status of individual outlets and power status of primary and secondary inputs. An input-voltage select switch lets you toggle between high (220, 230 or 240V) or low (200 or 208V) voltage.
Built-In LX Platform Interface Gives You Unrestricted Remote Access to Your Equipment 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
Easy to Install Horizontally in an EIA-Standard 19 in. Rack
This ATS PDU mounts in 1U of space in 19-inch rack or rack cabinet using the included brackets and hardware.
TAA-Compliant for GSA Schedule Purchases
The PDUMH15HVATNET is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
2-Year Warranty
The PDUMH15HVATNET is backed by a 2-year warranty, ensuring reliability and performance.
Packaged Quantity: 1
Product Type: PDU
Technical Information
Input Receptacles: 2 x IEC 60320 C14
Output Receptacles: 10 x IEC 60320 C13
Protection Type: Overload Protection
Power Description
Input Voltage: 230 V AC
Input Voltage Range: 200 V AC - 240 V AC
Output Voltage:
- 200 V AC
- 208 V AC
- 220 V AC
- 230 V AC
- 240 V AC
Power Rating (Watt): 2400 W
Input Current: 10 A
Management
Management:
- HTTP
- HTTPSPowerAlert
- SMTP
- SNMPv1
- SNMPv2
- SNMPv3
- Telnet
- SSH
- FTP
- DHCP
- BOOTP and NTP protocols
Interfaces/Ports
Network (RJ-45): Yes
Physical Characteristics
Mounting Orientation: Horizontal
Placement: Rack
Rack Height: 1U/2U
Height: 1.7"
Width: 17.3"
Depth: 14.4"
Weight (Approximate): 10.41 lb
Miscellaneous
Package Contents:
- PDUMH15HVATNET 10-Outlet PDU
- 10 x C14 plug lock inserts
- 2 x C13 to C14 power cords, 3.6 m (11.8 ft.)
- SNMPWEBCARD configuration cable
- 2 x Mounting brackets, horizontal
- 2 x Mounting brackets, vertical
- 6 x Screws
- Owner's manual
Environmentally Friendly: Yes
Environmental Certification: RoHS
TAA Compliant: Yes
Warranty
Limited Warranty: 2 Year