Image may not exactly match the product.

Tripp Lite

Tripp Lite PDUMV30 PDU Metered Single Phase Vert 24 NEMA 5-15/20R 30A

SKU:
PDUMV30
Shipping:
Calculated at Checkout
$591.00 $332.60
(You save $258.40 )

Image may not exactly match the product.

$591.00 $332.60
(You save $258.40 )
In Stock
In-Stock
Availability:
In Stock. Ships Same Business Day If Ordered Before 3pm PT

Condition:
New
Warranty Information
Limited Lifetime Warranty
View More

Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.

Hear What Our Customers Are Saying

slide 6 to 10 of 50

PDU Metered 120V 30A 5-15/20R 24 Outlet L5-30P Vertical 0URM

Tripp Lite single phase Metered PDU / Power Distribution Units offer real-time local reporting of load level in amps via built-in digital display. Enables visual monitoring of PDU load levels to prevent overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories
PDU Metered 120V 30A 5-15/20R 24 Outlet L5-30P Vertical 0URM

Reliable IT Power Distribution

The PDUMV30 provides 24 front-facing 5-15/20R outlets arranged in two individually breakered and metered 20A load banks and a 10-ft. power cord with L5-30P plug for distribution of alternate waveform AC power to supported equipment from a UPS system, generator or utility wall outlet. (Maximum PDU capacity is 30A, agency derated to 24A.) The PDUMV30 features a rugged all-metal case, high-quality outlets and plug, and dual 20A circuit breakers (one per outlet bank, protected to prevent them from being tripped accidentally). Unfiltered electrical pass-through without a power switch makes the PDUMV30 ideal for distributing alternate waveform UPS or generator power in rack enclosures, network closets and more.
Digital Current Meters

The PDUMV30 is equipped with dual digital LED meters, one for each individually breakered bank of 12 outlets. These meters enable IT personnel to visually monitor the load on each PDU outlet bank in real time, helping to prevent utility, generator, UPS or PDU overloads and ensuring proper load balance in complex redundant power applications.


Versatile Installation Options

The PDUMV30 is easy to integrate with a wide range of data center and network applications. It is configured for toolless button-mount 0U (vertical) installation in compatible rack enclosures. Included mounting hardware can be used to adapt the PDUMV30 for standard 2- and 4-post rack enclosures, raceway, wall-mount, workbench, under-counter and similar installations.
2-Year Warranty

The PDUMV30 comes with a 2-Year limited product warranty.

Digital Power Distribution Unit Vertical PDU 24 NEMA 5-15/20R 30A

 

 

Key Features

  • 30A single phase 120V Metered Power Distribution Unit / PDU (Agency de-rated to 24A continuous)
  • Set of two lighted meters report PDU output current in amps for each 12 outlet load bank
  • Attached NEMA L5-30P 30A 120V input plug with 10ft / 3m line cord
  • 0U vertical rackmount format installs using no rack spaces
  • 24 NEMA 5-15/20R output receptacles
  • Outlets are arranged in two 12 outlet load banks, each with separate 20A breaker and current metering
  • Toolless installation supported in button-mount compatible equipment racks
  • Bolt-down installation brackets support installation in other racks and additional surfaces
  • Cord retention brackets keep vital equipment plugs connected

Typical Applications

  • Ideal means of powering networking equipment in datacenters, computer rooms and network closets

Package Includes

  • PDUMV30 63.75 inch basic PDU with owner's manual
  • Set of 2 bolt-on plug retention brackets and installation hardware
  • Set of mounting brackets and installation hardware
OVERVIEW  
PDU Type Metered
OUTPUT  
Output Capacity Details 2.9kW (120V input), 3.0kW (127V input), 2.4kW (100V input);
30A maximum (agency de-rated to 24A continuous)
Frequency compatibility 50 / 60 Hz
Output nominal voltage 100-127V nominal, single phase
Overload protection Outlets are arranged in two separately breakered load banks.
The top 20A breaker covers outlets on the upper half, the
bottom 20A breaker covers outlets on the lower half of the PDU.
Each breakered bank covers 12 5-15/20R outlets.
Outlet quantity / type 24 5-15/20R (each outlet accepts 5-15P or 5-20P equipment plugs)
Outlet Type NEMA 5-15R, NEMA 5-20R
INPUT  
PDU Input Voltage 100; 120; 127
Maximum Input Amps (A) 30
Maximum Input Amps (A) Details Agency de-rated to 24A continuous
PDU Plug Type NEMA L5-30P
Input cord length (ft.) 10
Input cord length (m) 3
Phase Single-Phase
LEDS ALARMS & SWITCHES  
Switches n/a
Front panel LEDs Includes 2 built-in 2-character LED meters to display power
consumption of items plugged into each separately
breakered 20A loading bank.
PHYSICAL  
Shipping Dimensions (HWD/in) 64.5 x 3.5 x 4.75
Shipping Dimensions (HWD/cm) 163.8 x 8.9 x 12.1
Shipping weight (lbs) 13
Shipping weight (kg) 5.9
Unit Dimensions (HWD/in) 63.75 x 2.25 x 3.75
Unit Dimensions (HWD/cm) 162 x 5.7 x 9.5
Unit weight (lbs) 8
Unit weight (kg) 3.6
Material of construction Aluminum
Style Vertical Rackmount, Wallmount, Raceway, Workbench
Form factors supported 0u vertical installation in equipment racks,
plus under-counter and wallmount
PDU Form Factor Vertical (0U)
ENVIRONMENTAL  
Relative Humidity 0-95% non-condensing
CERTIFICATIONS  
Certifications Tested to UL60950-1 (USA, Canada), NOM (Mexico)
WARRANTY  
Product Warranty Period (Worldwide) 2-year limited warranty

Specs Overview