![Tripp Lite SMART3000RMXL2U Smart Pro 3000VA UPS Battery Backup 2U RM AVR 9 Outlets at Hummingbird Tripp Lite SMART3000RMXL2U Smart Pro 3000VA UPS Battery Backup 2U RM AVR 9 Outlets at Hummingbird](https://cdn11.bigcommerce.com/s-b9xom8/images/stencil/190x250/products/11238/8531/1015335628__11146.1667506377.jpg?c=2)
![Tripp Lite SMART3000RMXL2U Smart Pro 3000VA UPS Battery Backup 2U RM AVR 9 Outlets at Hummingbird Tripp Lite SMART3000RMXL2U Smart Pro 3000VA UPS Battery Backup 2U RM AVR 9 Outlets at Hummingbird](https://cdn11.bigcommerce.com/s-b9xom8/images/stencil/190x250/products/11238/8531/1015335628__11146.1667506377.jpg?c=2)
20+ Years Experience Helping IT Heroes
Free Solution Design With White Glove Engineers
Configuration & Installation Services
Equipment Trade-In Program
Exclusive Incentives, Special Pricing, & Financing
Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.
20+ Years Experience Helping IT Heroes
Free Solution Design With White Glove Engineers
Configuration & Installation Services
Equipment Trade-In Program
Exclusive Incentives, Special Pricing, & Financing
3000VA UPS Smart Pro Rack/Tower Line-Interactive 3kVA 9 outlets
OUTPUT | |
Output Volt Amp Capacity (VA) | 3000 |
Output kVA capacity (kVA) | 3 |
Output Watt Capacity (watts) | 2250 |
Output kW capacity | 2.25 |
Output power factor | 0.75 |
Output Capacity Details | Output capacity is reduced to 1600 watts in all external battery pack configurations |
Nominal Output Voltage(s) Supported | 120V |
Frequency compatibility | 60 Hz |
Output voltage regulation (line mode) | -14%, +6% |
Output voltage regulation (Battery mode) | +/- 5% |
Built-in UPS output receptacles | 8 5-15/20R outlet(s); 1 L5-30R outlet(s) |
Built-in controllable switched load banks | Two switchable single-outlet load banks |
Output circuit breaker | Two 20A output breakers protect 4 5-15/20R outlets each |
Output AC waveform (AC mode) | Pure Sine wave |
Output AC waveform (battery mode) | Pure Sine wave |
INPUT | |
Rated input current (at maximum load) | 24A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS input connection type | L5-30P |
UPS Input cord length (ft.) | 10 |
UPS Input cord length (m) | 3 |
Recommended Electrical Service | 30A 120V |
Phase | Single-Phase |
BATTERY | |
Full load runtime (minutes) | 3.5 min. (2250w) |
Half load runtime (minutes) | 10 min. (1125w) |
Expandable battery runtime | Extended runtime supported via optional external battery packs |
External battery pack compatibility | BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible) |
DC system voltage (VDC) | 48 |
Battery recharge rate (included batteries) | Less than 4.5 hours from 10% to 90% |
Replacement battery cartridge (internal UPS battery replacement) | RBC94-2U |
Battery Access | Front panel battery access door |
Battery replacement description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145 |
Overvoltage correction | Input voltages between 127 and 145 are reduced by 12% |
Undervoltage correction | Input voltages between 108 and 96 are boosted by 12% |
Severe undervoltage correction | Input voltages between 83 and 95 are boosted by 24% |
LEDS ALARMS & SWITCHES | |
Front panel LCD display | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
Alarms | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
Alarm cancel operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
Switches | 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression joule rating | 570 |
UPS AC suppression response time | Instantaneous |
EMI / RFI AC noise suppression | Yes |
PHYSICAL | |
Installation form factors supported with included accessories | 4 post 19 inch rackmount |
Installation form factors supported with optional accessories | 2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) |
Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 3.5 x 17.5 x 19.5 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 8.9 x 44.4 x 49.5 |
Rack Height | 2U |
Secondary form factor | Tower (requires 2-9USTAND) |
UPS / Power Module weight (lbs) | 62.8 |
UPS / Power Module weight (kg) | 28.5 |
UPS Shipping dimensions (height x width x depth / inches) | 7.9 x 21.7 x 24.2 |
UPS Shipping dimensions (height x width x depth / cm) | 20.1 x 61.5 x 62 |
Shipping weight (lbs) | 73.8 |
Shipping weight (kg) | 33.5 |
Cooling method | Fan |
UPS housing material | Steel |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 18900% |
AC mode efficiency rating (100% load) | 98% |
Operating Elevation (ft.) | 0-3000m / 0-10,000 ft. |
COMMUNICATIONS | |
Communications interface | USB (HID enabled); DB9 Serial; Slot for SNMP/Web interface |
Network monitoring port description | Supports detailed monitoring of UPS and site power conditions |
PowerAlert software | Included |
Communications cable | USB and DB9 cabling included |
WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER | |
Transfer time | 5 milliseconds (AC to battery); 1 millisecond (battery to AC) |
Low voltage transfer to battery power (setpoint) | 83 |
High voltage transfer to battery power (setpoint) | 145 |
SPECIAL FEATURES | |
Grounding lug | Includes back panel grounding lug |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
High availability UPS features | Hot swappable batteries |
Green & high efficiency features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI); ENERGY STAR Qualified |
WARRANTY | |
Product Warranty Period (Worldwide) | 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |