Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.
Hear What Our Customers Are Saying
-
20+ Years Experience Helping IT Heroes
Take advantage of 20+ years of expertise from a partner with available resources for large deployments, multi-site projects, and complex IT initiatives. We have the team to get the job done. -
Free Solution Design With White Glove Engineers
Solutions architects and project engineers will help you envision a successful outcome and give you personalized recommendations based on your unique needs. Free. Apply today. -
Configuration & Installation Services
Let us take care of configuring and installing your equipment so you can get back to business. Available nationwide. Apply today. -
Equipment Trade-In Program
Refreshing old hardware? Let us coordinate the recycling or destruction in an environmentally friendly and safe manner. As a bonus, working with us gives you access to specific trade-in discounts towards your network refresh. Apply today. -
Exclusive Incentives, Special Pricing, & Financing
After helping you build and validate your solution, we’ll include any applicable discounts, financing, and incentives applied to your project to guarantee you get the most value out of your IT investments through Hummingbird Networks. Apply today.
5000VA UPS Smart Pro Rack/Tower Line-Interactive 5kVA 208/120V 11 outlets
This product is very heavy and normally ships on a pallet. Specific arrangements must be made with Hummingbird Networks to arrange delivery after order is submitted.
Key Features
- 5000VA/3750 watt max. output power capacity compatible with North American 208V/60Hz input voltage
- Supports full output at either 208V or 120V
- 3U rack/tower UPS installs in standard 19 inch rack enclosures with an installed depth of only 25 inches / 63.5cm
- Protects sensitive networking equipment from blackouts, voltage fluctuations and transient surges
- Line Interactive Automatic Voltage Regulation (AVR) corrects 208V nominal input from 167 to 260VAC back to usable 208/120V levels without consuming battery power
- AVR circuits boost undervoltages by 12% and reduce overvoltages by 12%
- Network interfaces support simultaneous communications via USB, DB9 serial and SNMPWEBCARD slot
- Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
- Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, internal UPS temperature, AC line frequency, timed inverter shutoff, activate self-test and load bank output power control
- Built-in Emergency Power Off (EPO) interface with cable
- Sine wave output in AC and battery mode
- Expandable runtime with optional BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs
- Half/full load runtime of 20/8.5 minutes with internal batteries
- Includes 11 output receptacles (2 L6-20, 1 L6-30 & 8 NEMA 5-15/20R)
- Ships with installed L6-30P input plug, supports user supplied 50A replacement plug or hardwire input
- Integrated 8 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices
- 3 stage metered LEDs offer current monitoring and battery charge level
- Mains power and voltage regulation LEDs offer at-a-glance power status information
- Front panel switches support self-test and alarm cancel functions
- Included adjustable mounting rails support installation in 4 post 19 inch racks
- UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user is required
- Supports 2 post rackmount installation with optional 2POSTRMKIT accessory
- Supports upright tower placement with optional 2-9USTAND accessory
Package Includes
- SMART 5000XFMRXL UPS System
- PowerAlert Software and Cabling
- Mounting hardware for 4-post rackmount installation
- Instruction manual
OUTPUT | |
Output Volt Amp Capacity (VA) | 5000 |
Output kVA capacity (kVA) | 5 |
Output Watt Capacity (watts) | 3750 |
Output kW capacity | 3.8 |
Output power factor | 0.8 |
Nominal Output Voltage(s) Supported | 120V; 208V |
Frequency compatibility | 60 Hz |
Output voltage regulation (line mode) | 208 & 120V (+/- 10%) |
Output voltage regulation (Battery mode) | +/- 5% |
Built-in UPS output receptacles | 8 5-15/20R outlet(s); 2 L6-20R outlet(s); 1 L6-30R outlet(s) |
Built-in controllable switched load banks | Eight switchable single-outlet 5-15/20R load banks |
Output circuit breaker | 20A double pole breaker supports L6-20R outlets, 20A branch rated breaker (x2) supports 4 5-15/20R outlets each, L6-30R outlet is unbreakered |
Output AC waveform (AC mode) | Sine wave |
Output AC waveform (battery mode) | Pure Sine wave |
INPUT | |
Rated input current (at maximum load) | 27A |
Nominal Input Voltage(s) Supported | 208V AC |
UPS input connection type | L6-30P |
UPS Input cord length (ft.) | 10 |
UPS Input cord length (m) | 3 |
Recommended Electrical Service | 30A 208V |
Phase | Single-Phase |
BATTERY | |
Full load runtime (minutes) | 8.5 min. (3750w) |
Half load runtime (minutes) | 20 min. (1875w) |
Expandable battery runtime | Extended runtime supported via optional external battery packs |
External battery pack compatibility | BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible) |
DC system voltage (VDC) | 48 |
Battery recharge rate (included batteries) | Less than 4 hours from 10% to 90% |
Replacement battery cartridge (internal UPS battery replacement) | RBC94-3U (quantity 3) |
Battery Access | Front panel battery access door |
Battery replacement description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 167 to 260 |
Overvoltage correction | Input voltages between 228 and 260 are reduced by 12% |
Undervoltage correction | Input voltages between 167 and 194 are boosted by 12% |
LEDS ALARMS & SWITCHES | |
LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
Alarms | Audible alarm indicates power-failure, overload and low-battery conditions |
Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression joule rating | 1020 |
UPS AC suppression response time | Instantaneous |
EMI / RFI AC noise suppression | Yes |
PHYSICAL | |
Installation form factors supported with included accessories | 4 post 19 inch rackmount |
Installation form factors supported with optional accessories | 2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND) |
Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 5.2 x 17.5 x 25 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 13.3 x 44.4 x 63.5 |
Rack Height | 3U |
Secondary form factor | Tower (requires 2-9USTAND) |
UPS / Power Module weight (lbs) | 143.3 |
UPS / Power Module weight (kg) | 65.1 |
UPS Shipping dimensions (height x width x depth / inches) | 11.2 x 23 x 31.5 |
UPS Shipping dimensions (height x width x depth / cm) | 28.6 x 58.4 x 80 |
Shipping weight (lbs) | 181.9 |
Shipping weight (kg) | 82.6 |
Cooling method | Fan |
UPS housing material | Steel |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 67110% |
Battery mode BTU / hr. (full load) | 141670% |
AC mode efficiency rating (100% load) | 97% |
COMMUNICATIONS | |
Communications interface | USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
Network monitoring port description | Supports detailed monitoring of UPS and site power conditions |
PowerAlert software | Included |
Communications cable | USB and DB9 cabling included |
WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER | |
Transfer time | 2-4 milliseconds |
Low voltage transfer to battery power (setpoint) | 167 |
High voltage transfer to battery power (setpoint) | 260 |
SPECIAL FEATURES | |
Grounding lug | Back panel grounding lug |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
High availability UPS features | Hot swappable batteries |
Green & high efficiency features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) |
WARRANTY | |
Product Warranty Period (Worldwide) | 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |