Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.
Hear What Our Customers Are Saying
-
20+ Years Experience Helping IT Heroes
Take advantage of 20+ years of expertise from a partner with available resources for large deployments, multi-site projects, and complex IT initiatives. We have the team to get the job done. -
Free Solution Design With White Glove Engineers
Solutions architects and project engineers will help you envision a successful outcome and give you personalized recommendations based on your unique needs. Free. Apply today. -
Configuration & Installation Services
Let us take care of configuring and installing your equipment so you can get back to business. Available nationwide. Apply today. -
Equipment Trade-In Program
Refreshing old hardware? Let us coordinate the recycling or destruction in an environmentally friendly and safe manner. As a bonus, working with us gives you access to specific trade-in discounts towards your network refresh. Apply today. -
Exclusive Incentives, Special Pricing, & Financing
After helping you build and validate your solution, we’ll include any applicable discounts, financing, and incentives applied to your project to guarantee you get the most value out of your IT investments through Hummingbird Networks. Apply today.
750VA UPS Smart Pro Rack/Tower Extended Run Line-Interactive 6 outlets
Key Features
- Tripp Lite SMART750RMXL2U line interactive 2U rack/tower UPS with 750VA / .75kVA / 600W capacity and extended runtime options
- Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 147V
- NEMA 5-15P input plug; 6 NEMA 5-15R output receptacles, Two independently switched output load banks
- Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages
- High 95% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions
- Internal batteries offer 20.7minutes at 50% load (300W) and 8.5 minutes at 100% load (600W)
- Extended runtime is available with optional BP24V15RT2U (limit 1), BP24V28-2U (limit 1), BP24V70-3U (multi-pack compatible) and BP24V36-2US (multi-pack compatible); Output is reduced to 450 watts maximum with external battery packs
- External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment
- Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed UPS and site power information
- LCD interface also supports a number of advanced user setup and operating preferences
- Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional 2-9USTAND enables tower placement
- Built-in USB, RS-232 and optional SNMPWEBCARD accessory monitoring options
- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- Included PowerAlert UPS monitoring software; Built-in Emergency Power Off (EPO) interface with cable
Package Includes
- SMART750RMXL2U UPS System
- PowerAlert software with USB, Serial & EPO cabling
- 4 post installation kit
- Owner's manual
OUTPUT | |
Output Volt Amp Capacity (VA) | 750 |
Output kVA capacity (kVA) | 0.75 |
Output Watt Capacity (watts) | 600 |
Output kW capacity | 0.6 |
Output power factor | 0.8 |
Output Capacity Details | Output derates to 450 watts in all external battery pack configurations |
Nominal Output Voltage(s) Supported | 120V |
Frequency compatibility | 60 Hz |
Output voltage regulation (line mode) | -21%, +8% |
Output voltage regulation (Battery mode) | +/- 5% |
Built-in UPS output receptacles | 6 5-15R outlet(s) |
Built-in controllable switched load banks | Two switchable two-outlet 5-15R load banks |
Output AC waveform (AC mode) | Sine wave |
Output AC waveform (battery mode) | Pure Sine wave |
INPUT | |
Rated input current (at maximum load) | 7.5A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS input connection type | 5-15P |
Input circuit breaker | 10A |
UPS Input cord length (ft.) | 10 |
UPS Input cord length (m) | 3.05 |
Recommended Electrical Service | 15A 120V |
Phase | Single-Phase |
BATTERY | |
Full load runtime (minutes) | 8.5 min. (600w) |
Half load runtime (minutes) | 20.7 min. (300w) |
Expandable battery runtime | Extended runtime supported via optional external battery packs |
External battery pack compatibility | BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible); BP24V36-2US (multi-pack compatible) |
DC system voltage (VDC) | 24 |
Battery recharge rate (included batteries) | Less than 4.5 hours from 10% to 90% |
Replacement battery cartridge (internal UPS battery replacement) | See Tripp Lite UPS Replacement battery selector |
Battery Access | Front panel battery access door |
Battery replacement description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147 |
Overvoltage correction | Input voltages between 128 and 147 are reduced by 12% |
Undervoltage correction | Input voltages between 83 and 107 are boosted by 14% |
LEDS ALARMS & SWITCHES | |
LED Indicators | Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
Alarms | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
Alarm cancel operation | Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
Switches | 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression joule rating | 570 joules |
EMI / RFI AC noise suppression | Yes |
PHYSICAL | |
Installation form factors supported with optional accessories | 2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) |
Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 3.45 x 17.35 x 13.15 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 8.8 x 44.1 x 33.4 |
Rack Height | 2U |
Secondary form factor | Tower (requires 2-9USTAND) |
UPS / Power Module weight (lbs) | 35.4 |
UPS / Power Module weight (kg) | 16.1 |
UPS Shipping dimensions (height x width x depth / inches) | 7.9 x 22.85 x 19.3 |
UPS Shipping dimensions (height x width x depth / cm) | 20.1 x 58 x 49 |
Shipping weight (lbs) | 46.4 |
Shipping weight (kg) | 21.1 |
Cooling method | Fan |
UPS housing material | Steel |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 109 |
AC mode efficiency rating (100% load) | 95% |
COMMUNICATIONS | |
Communications interface | USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
Network monitoring port description | Supports detailed monitoring of UPS and site power conditions |
PowerAlert software | Included |
Communications cable | USB and DB9 cabling included |
WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER | |
Transfer time | 4 milliseconds (AC to battery mode), 2 milliseconds (Battery to AC mode) |
Low voltage transfer to battery power (setpoint) | 83 |
High voltage transfer to battery power (setpoint) | 147 |
SPECIAL FEATURES | |
Grounding lug | Back panel grounding lug |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
High availability UPS features | Hot swappable batteries |
Green & high efficiency features | Individually controllable load banks |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI) |
WARRANTY | |
Product Warranty Period (Worldwide) | 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |