3000VA UPS Smart Online Rackmount 2U Economy Mode 7 outlets
DISTRIBUTED SERVER ROOMS; NETWORK CLOSETS; SMALL BUSINESS NETWORKS; SMALL BUSINESS PHONE SYSTEM
OUTPUT | |
Output Volt Amp Capacity (VA) | 3000 |
Output kVA capacity (kVA) | 3 |
Output Watt Capacity (watts) | 2500 |
Output kW capacity | 2.5 |
Output power factor | 19:55 |
Output Capacity Details | Max output is 3000VA 2400W at 100V, 110V, 115V nominal settings |
Crest Factor | 3:01 |
Nominal Output Voltage(s) Supported | 100V; 110V; 115V; 120V; 127V |
Nominal Voltage details | 120V default |
Frequency compatibility | 50 / 60 Hz |
Frequency compatibility details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start. Frequency conversion from 60 to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates by 25% during frequency conversion operation. |
Output voltage regulation (line mode) | +/- 2% |
Output voltage regulation (Economy line mode) | -12%, + 10% |
Output voltage regulation (Battery mode) | +/- 2% |
Built-in UPS output receptacles | 6 5-15/20R outlet(s); 1 L5-30R outlet(s) |
Built-in controllable switched load banks | Two switchable three-outlet load banks |
Output circuit breaker | 20A (x2) - each breaker protects 3 5-15/20R outlets, L5-30R outlet is un-breakered |
Output AC waveform (AC mode) | Pure Sine wave |
Output AC waveform (battery mode) | Pure Sine wave |
INPUT | |
Rated input current (at maximum load) | 24A |
Nominal Input Voltage(s) Supported | 100V AC; 110V AC; 115V AC; 120V AC; 127V AC |
UPS input connection type | L5-30P |
Recommended Electrical Service | 30A 120V |
Input cord length (ft.) | 10 |
Input cord length (m) | 3 |
Phase | Single-Phase |
BATTERY | |
Full load runtime (minutes) | 6 min. (2500w) |
Half load runtime (minutes) | 15 min. (1250w) |
Expandable battery runtime | Supports extended runtime with optional external battery packs |
External battery pack compatibility | BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) |
DC system voltage (VDC) | 72 |
Battery recharge rate (included batteries) | Less than 4.8 hours from 10% to 90% |
Replacement battery cartridge (internal UPS battery replacement) | RBC96-2U |
Battery Access | Front panel battery access door |
Battery replacement description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
Voltage regulation description | Online, double-conversion power conditioning |
Overvoltage correction | 2% output voltage regulation during overvoltages to 144 |
Undervoltage correction | 2% output voltage regulation during undervoltages to 80 |
Severe undervoltage correction | 2% output voltage regulation during undervoltages to 70V (under 66% load only) or 60V (under 33% load only) |
LEDS ALARMS & SWITCHES | |
LED Indicators | 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats |
Alarms | Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation |
Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression joule rating | 504 joules |
EMI / RFI AC noise suppression | Yes |
AC suppression response time | Instantaneous |
PHYSICAL | |
Installation form factors supported with optional accessories | 2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) |
Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 3.5 x 17.3 x 26 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 8.9 x 43.9 x 66 |
Rack Height | 2U |
Secondary form factor | Tower (requires 2-9USTAND) |
UPS / Power Module weight (lbs) | 68.8 |
UPS / Power Module weight (kg) | 31.2 |
UPS Shipping dimensions (height x width x depth / inches) | 9 x 22 x 32.8 |
UPS Shipping dimensions (height x width x depth / cm) | 22.9 x 55.9 x 83.3 |
Shipping weight (lbs) | 7830% |
Shipping weight (kg) | 35.5 |
Cooling method | Fan |
UPS housing material | Steel |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius. |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 100000% |
AC economy mode BTU / hr. (full load) | 24100% |
Battery mode BTU / hr. (full load) | 150000% |
AC mode efficiency rating (100% load) | 89% |
AC economy mode efficiency rating (100% load) | 97% |
COMMUNICATIONS | |
Communications interface | USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface |
Network monitoring port description | Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications |
PowerAlert software | Included |
Communications cable | USB and DB9 cabling included |
WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER | |
Transfer time | No transfer time (0 ms.) in online, double-conversion mode |
Low voltage transfer to battery power (setpoint) | 80V (100% load), 70V (66% load), 60V (33% load) |
High voltage transfer to battery power (setpoint) | 144 |
SPECIAL FEATURES | |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
High availability UPS features | Automatic inverter bypass; Hot swappable batteries |
Green & high efficiency features | High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) |
WARRANTY | |
Product Warranty Period (Worldwide) | 2-year limited warranty |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |