Image may not exactly match the product.

Tripp Lite

Tripp Lite SU6000RT4UHVHW SmartOnline 6000VA UPS Backup RM 200-240V

SKU:
SU6000RT4UHVHW
Shipping:
$149.00 (Fixed Shipping Cost)
$5,928.62 $3,400.25
(You save $2,528.37 )

Image may not exactly match the product.

$5,928.62 $3,400.25
(You save $2,528.37 )
Availability:
Currently out of stock, pre-order may be available

Condition:
New
Warranty Information
2 Years
View More
Out of Stock

Out of Stock.

Request a quote for re-stock information.

Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.

Hear What Our Customers Are Saying

slide 6 to 10 of 50

SU6000RT4UHVHW SmartOnline® Hot-Swappable Double-Conversion Rack/Tower Sine Wave UPS with Bypass Switch, Expandable Runtime, Network Slot and LCD

POWER PROTECTION AND EXPANDABLE BATTERY BACKUP
for servers and network hardware

This on-line, double-conversion UPS system protects critical network systems from damage, downtime and data loss.
  • True on-line, double-conversion operation delivers pure sine wave output, precise voltage regulation and isolation from power problems.
  • Expandable battery backup supports critical systems during outages.
  • Bypass switch allows UPS power module to be removed for maintenance, repair or replacement without requiring connected equipment downtime.
  • LCD/LED control panel displays power conditions and permits easy access to settings.
  • Network card slot supports optional remote access and network management.
  • USB and DB9 serial ports connect to computers for power management.
  • 2-year warranty and $250,000 insurance reflect commitment to reliability.
SU6000RT4UHVHW SmartOnline® Hot-Swappable Double-Conversion Rack/Tower Sine Wave UPS with Bypass Switch, Expandable Runtime, Network Slot and LCD
Why is this UPS a Good Investment? 4:06

Why is this UPS a Good Investment?

The success of your organization depends on critical information systems like servers and network hardware. If your critical systems don't have reliable power, employees can't work, communications go down, automated systems malfunction and productivity grinds to a halt. It would be nice if utility power was always reliable, but it isn't. Between severe weather, the aging electrical grid and hazards lurking inside your own walls, your servers and network hardware are under attack from power problems. Even a brief loss of power or a momentary surge can damage your equipment, corrupt your data, bring down your network and hurt your bottom line.

The potential costs of downtime are alarming. Surveyed averages range from $1,167 per minute for mid-size businesses (IDC) to $7,908 per minute for larger operations (Ponemon Institute). For a tiny fraction of these costs, you can prevent damage, downtime and data loss by installing this SmartOnline UPS system. True on-line double conversion is the highest level of power protection available. It provides precise voltage regulation, delivers continuous sine wave output and isolates equipment from power problems. This UPS system also has a high power factor, allowing you to connect a heavier load without overloading the UPS.

Common Applications

Protect Mission-Critical Servers and Network Hardware
Application Servers, Storage Servers, Database Servers, File Servers, Virtualization Servers, Proxy Servers, Web Servers, Cloud Platform Servers, Media Servers, VoIP Servers, Converged Infrastructure, Network Switches, PoE Switches, Firewalls, Network Appliances, Bridges, Gateways, Routers

Protect Equipment with Active PFC Power Supplies
Active PFC power supplies found in many devices require sine wave power.

Expandable Battery Backup

  • Half-Load Runtime: This UPS system will support a 50% load (2700W) for up to 8.5 minutes using the included batteries.
  • Extended Runtime: This UPS system allows you to connect one or more optional external battery packs to provide additional backup runtime. Some external battery packs can also be daisy-chained, allowing you to scale runtime to match almost any application requirement.
  • Hot-Swappable Batteries: You can add or replace batteries without turning off the UPS system and disrupting the operation of connected equipment.

On-Line, Double-Conversion Operation

This UPS system provides the highest level of power protection available:
  • Continuous on-line, double-conversion operation provides precise voltage regulation and sine wave output. It isolates connected equipment from most power problems, including blackouts, brownouts, overvoltages, transient voltage surges, electromagnetic (EMI/RFI) line noise, harmonic distortion, electrical impulses and frequency variations.
  • Zero transfer time to battery prevents malfunctions and reboots of sensitive equipment potentially caused by the transition from line power to battery-derived power during outages.
  • Fault-tolerant automatic bypass maintains utility output and avoids downtime during a variety of fault and overload conditions.

Hot-Swappable UPS with Bypass Switch

All SmartOnline UPS systems have hot-swappable batteries and an automatic internal bypass that delivers power directly to connected equipment in the case of an internal fault or severe overload. These features support the continuous availability of critical systems like servers and network hardware connected to the UPS. This UPS system also includes a detachable PDU with bypass switch to provide even higher system availability. When the switch is set to "bypass," you can completely remove the UPS power module for maintenance, repair or replacement without requiring downtime. The detachable PDU remains connected to the AC input power source and continues to supply power to connected equipment.

Flexible Management Options

There are several ways to manage this UPS system:
  1. Use the multifunction LCD screen for comprehensive local management.
  2. Use the USB port with your computer's built-in power management features.
  3. Use the USB or serial port with your computer and Tripp Lite's PowerAlert® software. PowerAlert provides enhanced features like automatic file saves, event notification, logging, advanced device control and an SNMP agent that supports centralized management. Select UPS models include a convenient CD-ROM, or you can download the latest version of PowerAlert for free at Tripp Lite's website.
  4. Install an optional network card to enable standalone network management via SNMP, Web, SSH or telnet. The network card has an Ethernet port and embedded interface, allowing you to access advanced monitoring, control and notification features without directly connecting the UPS system to a computer. The network card also supports connecting one or more optional sensors for remote temperature, humidity and contact closure monitoring. (Available network cards and sensors include TLNETCARD with TLNETEM sensor; WEBCARDLX with E2MT, E2MTDO, E2MTDI and E2MTHDI sensors; and SNMPWEBCARD with ENVIROSENSE sensor. Refer to each model for specific features.)

Multifunction LCD/LED Control Panel

The convenient LCD/LED control panel provides easy access to detailed UPS settings and information. The illuminated LCD screen displays a variety of helpful data, including input/output voltage, input/output frequency, load level and battery level. An LED block diagram supplements the LCD screen by indicating the UPS operating mode and power conditions. The control panel also allows you to change the UPS system's operating mode and other settings. The control panel provides more information and greater control than comparable models, allowing you to diagnose and respond to power problems at the rack before they cause downtime.

Eco-Friendly Design

  • Economy Mode: This UPS system provides user-selectable economy mode operation to increase efficiency and cut operating costs. In economy mode, the UPS system suspends double conversion and operates with increased efficiency as long as input power quality is satisfactory. If input power quality becomes unsatisfactory, the UPS system immediately resumes double conversion until power quality returns to normal.
  • User-Replaceable Battery: This UPS system has a user-replaceable, recyclable battery, allowing it to remain in service instead of going to a landfill.
  • RoHS Compliance: This UPS system complies with the RoHS (Restriction of Hazardous Substances) Directive, limiting the use of hazardous substances in manufacturing.

Dependable Service from an Industry Leader

Service and Support
  • 2-Year Product Warranty: If this UPS system (including the internal battery) proves defective in material or workmanship within that period, Tripp Lite will repair or replace it at no charge.
  • $250,000 Insurance: Tripp Lite will repair or replace connected equipment damaged by surges – even lightning strikes!
  • Free Tech Support: Chicago-based, in-house tech specialists are available by phone, email and chat.
Industry Leader
  • Over 95 Years: Founded in 1922, Tripp Lite has a long-established and proven track record of providing reliable products and responsive customer service.
  • Trusted Name: From the smallest office to the largest data center, customers worldwide trust Tripp Lite to power, protect, manage and connect valuable IT equipment.
  • Third-Party Safety Testing and ISO 9001 Certification

Key Specifications

Model: SU6000RT4UHVHW
Load Capacity:
6 kVA (5.4 kW)
Power Factor: 0.9
Nominal AC Input: 200V; 208V; 220V; 230V; 240V (50/60 Hz)
Nominal AC Output: 200V; 208V; 220V; 230V; 240V (50/60 Hz)
Output Voltage Regulation (Line Mode): +/- 2%
AC Outlets: Hardwire
Output Waveform (AC Mode): Pure Sine Wave
Output Waveform (Battery Mode): Pure Sine Wave
AC Input Connection: Hardwire
Half-Load Runtime (Included Batteries): 8.5 min. (2700W Load)
User-Replaceable Battery: Yes (RBC5-192)
Expandable Battery Runtime:
Yes (Requires Optional External Battery Pack)
Compatible External Battery Packs:
BP192V12-3U; BP192V557C-1PH; BP192V787C-1PH; BP192V1037C-1PH; BP192V1407C-1PH; BP192V5RT2U (Limit 1)
Communications: USB Port (HID-Compliant); Serial Port (DB9); Network Card Slot; EPO
Primary Form Factor: 4U Rack (Supports 4-post rack installation with included kit. Add 2POSTRMKITHD for 2-post rack installation. Add 2-9USTAND for tower installation.)
Dimensions: 6.85 x 17.5 x 20.67 in. (17.4 x 44.5 x 52.5 cm)
Unit Weight: 116.2 lb. (52.7 kg)
Standards: UL 1778 (USA); CSA (Canada); CE; FCC A (EMI); RoHS
Product Warranty (Worldwide): 2-Year Limited Warranty
Connected Equipment Insurance (U.S., Canada and Puerto Rico): $250,000
What's Included: UPS, 4-Post Rack Installation Kit, USB/Serial/EPO Cabling, PowerAlert Software, Manual

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Actual products may differ slightly from photos. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. Runtime varies with load, battery condition and other factors. Go to Tripp Lite's website for more information, including complete warranty terms and conditions.

6000VA UPS Smart Online High Efficiency HW 4U RM 6kVA 200-240V

This product is very heavy and normally ships on a pallet. Specific arrangements must be made with Hummingbird Networks to arrange delivery after order is submitted.

 

 

Key Features

  • Tripp Lite SU6000RT4UHVHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a single 4U rack/tower compatible housing
  • Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
  • Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
  • Detachable back panel PDU contains hardwire input and output connections, plus manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment
  • Hardwire input and output connections supported
  • Included rail kit supports 4U 19 inch rackmount installation in 4 post racks
  • Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (1 required for SU6000RT4UHVHW)
  • Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UHVHW)
  • Maximum installed rack depth of only 20.7 in. / 52.6cm inches
  • Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode
  • Corrects brownouts to 156V at full load (100V at 50% load or less)
  • Corrects overvoltages to 290V at full load (300V at 90% load or less)
  • Supports 50/60Hz operation for worldwide frequency compatibility
  • Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
  • High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs
  • Network-grade AC surge and noise suppression
  • Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces
  • UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part # RELAYIOCARD)
  • Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces
  • Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification
  • Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)
  • HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
  • Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices
  • Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major
  • UPS functions with support for a variety of control options to support advanced UPS settings and configurations
  • LED/LCD display panel rotates for viewing in rackmount or tower configurations
  • Supports Emergency Power Off (EPO) via built-in interface
  • Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
  • BP192V12-3U external battery packs are field replaceable and hot swappable
  • Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
  • Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
OUTPUT  
Output Volt Amp Capacity (VA) 6000
Output kVA capacity (kVA) 6
Output Watt Capacity (watts) 5400
Output kW capacity 5.4
Output power factor 21:36
Crest Factor 3:01
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
Frequency compatibility 50 / 60 Hz
Frequency compatibility details Output frequency matches input nominal on startup;
Frequency conversion mode enables conversion of
60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Output voltage regulation (line mode) +/- 2%
Output voltage regulation (Economy line mode) +/- 10%
Output voltage regulation (Battery mode) +/- 2%
Built-in UPS output receptacles Hardwire
Output receptacle details Hardwire input and output connections are mounted
on a detachable PDU backplate with bypass switch
to enable hot-swappable power module replacement
Output AC waveform (AC mode) Pure Sine wave
Output AC waveform (battery mode) Pure Sine wave
INPUT  
Rated input current (at maximum load) 31.9A (200V), 30.6A (208V), 29A (220V),
27.7A (230V), 26.6A (240V)
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS input connection type Hardwire
Recommended Electrical Service 40A (200/208v); 30A (220/230/240v)
Phase Single-Phase
BATTERY  
Full load runtime (minutes) 2 minutes (5400 watts)
Half load runtime (minutes) 8.5 minutes (2700 watts)
Expandable battery runtime Runtime is expandable with external battery packs
External battery pack compatibility BP192V12-3U
DC system voltage (VDC) 192
Battery recharge rate (included batteries) 6 hours from 10% to 90% (internal batteries)
Replacement battery cartridge
(internal UPS battery replacement)
RBC5-192
Battery Access Front panel battery access door
Battery replacement description Hot-swappable, user replaceable internal batteries
VOLTAGE REGULATION  
Voltage regulation description Online, double-conversion power conditioning
Overvoltage correction Corrects overvoltages as high as
300V (<90% load) and 280V (full load)
Undervoltage correction Corrects undervoltages as low as
100 (<50% load) and 155V (full load); derates linearly
LEDS ALARMS & SWITCHES  
LED Indicators 6 LEDs indicate line power, online mode, economy/bypass
mode, on-battery, charger and AC output status; LCD screen
offers additional information and control options
Alarms Unique audible alarms for all major UPS,
environmental and power conditions (see manual)
Alarm cancel operation Alarm cancel switch
Switches Includes main power off/on switch, plus 2 switches
to set and execute scrollable LCD functions. A manual
bypass switch featured on the detachable PDU allows
for complete removal of the UPS during routine maintenance
without disrupting power to connected loads
SURGE / NOISE SUPPRESSION  
UPS AC suppression response time Instantaneous
EMI / RFI AC noise suppression Yes
PHYSICAL  
Installation form factors supported
with optional accessories
2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)
Primary form factor Rackmount
UPS / Power Module dimensions
in primary form factor
(height x width x depth / inches)
6.85 x 17.5 x 20.7
UPS / Power Module dimensions
in primary form factor
(height x width x depth / cm)
17.4 x 44.5 x 52.6
Rack Height 4U
Secondary form factor Tower
UPS / Power Module weight (lbs) 116.2
UPS / Power Module weight (kg) 52.8
UPS Shipping dimensions
(height x width x depth / inches)
12.7 x 23.6 x 29.1
UPS Shipping dimensions
(height x width x depth / cm)
32.3 x 59.9 x 73.9
Shipping weight (lbs) 15700%
Shipping weight (kg) 7110%
Cooling method Fans
UPS housing material Steel
ENVIRONMENTAL  
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC mode BTU / hr. (full load) 1767
AC economy mode BTU / hr. (full load) 76500%
Battery mode BTU / hr. (full load) 178400%
AC mode efficiency rating (100% load) 90%
AC economy mode efficiency rating (100% load) 96%
Operating Elevation (ft.) 0-3000m (0 to 10,000 ft.)
Audible Noise 60 dBA at front side 1 meter
Operating Elevation (m) 0-3000 m
COMMUNICATIONS  
Communications interface USB (HID enabled); DB9 Serial;
EPO (emergency power off); Slot for SNMP/Web interface
Network monitoring port description Additional contact closure support with optional
RELAYIOCARD and RELAYIOMINI interface cards.
RELAYIOMINI installation requires removal of panel
containing USB ports
PowerAlert software Included
Communications cable USB, DB9 serial and EPO cables included
WatchDog compatibility Yes
LINE / BATTERY TRANSFER  
Transfer time No transfer time (0 ms.) in online, double-conversion mode
Transfer time (economy mode) 8 ms. typical power failure response in optional economy mode
Low voltage transfer to battery power (setpoint) 156V (full load) / 100V (50% load or less, derates linearly)
High voltage transfer to battery power (setpoint) 280V (full load) / 300V (90% load or less)
SPECIAL FEATURES  
Cold Start (startup in battery
mode during a power failure)
Cold-start operation supported
High availability UPS features Automatic inverter bypass; Manual bypass switch;
Detachable hot-swap PDU; Hot swappable UPS
power module; Hot swappable batteries
Green & high efficiency features High efficiency economy mode operation; Support for
daily startup and shutoff; Schedulable daily hours of
economy mode operation
CERTIFICATIONS  
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada);
CE; Meets FCC Part 15 Category A (EMI);
ROHS (Restriction of Hazardous Substances)
UPS Certification details IEC 61000-4-5 1995 B Surge Immunity
WARRANTY  
Product Warranty Period (Worldwide) 2-year limited warranty

Specs Overview

Detailed Specs