Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.
Hear What Our Customers Are Saying
-
20+ Years Experience Helping IT Heroes
Take advantage of 20+ years of expertise from a partner with available resources for large deployments, multi-site projects, and complex IT initiatives. We have the team to get the job done. -
Free Solution Design With White Glove Engineers
Solutions architects and project engineers will help you envision a successful outcome and give you personalized recommendations based on your unique needs. Free. Apply today. -
Configuration & Installation Services
Let us take care of configuring and installing your equipment so you can get back to business. Available nationwide. Apply today. -
Equipment Trade-In Program
Refreshing old hardware? Let us coordinate the recycling or destruction in an environmentally friendly and safe manner. As a bonus, working with us gives you access to specific trade-in discounts towards your network refresh. Apply today. -
Exclusive Incentives, Special Pricing, & Financing
After helping you build and validate your solution, we’ll include any applicable discounts, financing, and incentives applied to your project to guarantee you get the most value out of your IT investments through Hummingbird Networks. Apply today.
6000VA UPS Smart Online High Efficiency HW 4U RM 6kVA 200-240V
This product is very heavy and normally ships on a pallet. Specific arrangements must be made with Hummingbird Networks to arrange delivery after order is submitted.
Key Features
- Tripp Lite SU6000RT4UHVHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a single 4U rack/tower compatible housing
- Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
- Detachable back panel PDU contains hardwire input and output connections, plus manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment
- Hardwire input and output connections supported
- Included rail kit supports 4U 19 inch rackmount installation in 4 post racks
- Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (1 required for SU6000RT4UHVHW)
- Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UHVHW)
- Maximum installed rack depth of only 20.7 in. / 52.6cm inches
- Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode
- Corrects brownouts to 156V at full load (100V at 50% load or less)
- Corrects overvoltages to 290V at full load (300V at 90% load or less)
- Supports 50/60Hz operation for worldwide frequency compatibility
- Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
- High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs
- Network-grade AC surge and noise suppression
- Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces
- UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part # RELAYIOCARD)
- Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces
- Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification
- Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)
- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices
- Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major
- UPS functions with support for a variety of control options to support advanced UPS settings and configurations
- LED/LCD display panel rotates for viewing in rackmount or tower configurations
- Supports Emergency Power Off (EPO) via built-in interface
- Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
- BP192V12-3U external battery packs are field replaceable and hot swappable
- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
OUTPUT | |
Output Volt Amp Capacity (VA) | 6000 |
Output kVA capacity (kVA) | 6 |
Output Watt Capacity (watts) | 5400 |
Output kW capacity | 5.4 |
Output power factor | 21:36 |
Crest Factor | 3:01 |
Nominal Output Voltage(s) Supported | 200V; 208V; 220V; 230V; 240V |
Frequency compatibility | 50 / 60 Hz |
Frequency compatibility details | Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating) |
Output voltage regulation (line mode) | +/- 2% |
Output voltage regulation (Economy line mode) | +/- 10% |
Output voltage regulation (Battery mode) | +/- 2% |
Built-in UPS output receptacles | Hardwire |
Output receptacle details | Hardwire input and output connections are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement |
Output AC waveform (AC mode) | Pure Sine wave |
Output AC waveform (battery mode) | Pure Sine wave |
INPUT | |
Rated input current (at maximum load) | 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V) |
Nominal Input Voltage(s) Supported | 200V AC; 208V AC; 220V AC; 230V AC; 240V AC |
UPS input connection type | Hardwire |
Recommended Electrical Service | 40A (200/208v); 30A (220/230/240v) |
Phase | Single-Phase |
BATTERY | |
Full load runtime (minutes) | 2 minutes (5400 watts) |
Half load runtime (minutes) | 8.5 minutes (2700 watts) |
Expandable battery runtime | Runtime is expandable with external battery packs |
External battery pack compatibility | BP192V12-3U |
DC system voltage (VDC) | 192 |
Battery recharge rate (included batteries) | 6 hours from 10% to 90% (internal batteries) |
Replacement battery cartridge (internal UPS battery replacement) | RBC5-192 |
Battery Access | Front panel battery access door |
Battery replacement description | Hot-swappable, user replaceable internal batteries |
VOLTAGE REGULATION | |
Voltage regulation description | Online, double-conversion power conditioning |
Overvoltage correction | Corrects overvoltages as high as 300V (<90% load) and 280V (full load) |
Undervoltage correction | Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly |
LEDS ALARMS & SWITCHES | |
LED Indicators | 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options |
Alarms | Unique audible alarms for all major UPS, environmental and power conditions (see manual) |
Alarm cancel operation | Alarm cancel switch |
Switches | Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression response time | Instantaneous |
EMI / RFI AC noise suppression | Yes |
PHYSICAL | |
Installation form factors supported with optional accessories | 2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND) |
Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 6.85 x 17.5 x 20.7 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 17.4 x 44.5 x 52.6 |
Rack Height | 4U |
Secondary form factor | Tower |
UPS / Power Module weight (lbs) | 116.2 |
UPS / Power Module weight (kg) | 52.8 |
UPS Shipping dimensions (height x width x depth / inches) | 12.7 x 23.6 x 29.1 |
UPS Shipping dimensions (height x width x depth / cm) | 32.3 x 59.9 x 73.9 |
Shipping weight (lbs) | 15700% |
Shipping weight (kg) | 7110% |
Cooling method | Fans |
UPS housing material | Steel |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 1767 |
AC economy mode BTU / hr. (full load) | 76500% |
Battery mode BTU / hr. (full load) | 178400% |
AC mode efficiency rating (100% load) | 90% |
AC economy mode efficiency rating (100% load) | 96% |
Operating Elevation (ft.) | 0-3000m (0 to 10,000 ft.) |
Audible Noise | 60 dBA at front side 1 meter |
Operating Elevation (m) | 0-3000 m |
COMMUNICATIONS | |
Communications interface | USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
Network monitoring port description | Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports |
PowerAlert software | Included |
Communications cable | USB, DB9 serial and EPO cables included |
WatchDog compatibility | Yes |
LINE / BATTERY TRANSFER | |
Transfer time | No transfer time (0 ms.) in online, double-conversion mode |
Transfer time (economy mode) | 8 ms. typical power failure response in optional economy mode |
Low voltage transfer to battery power (setpoint) | 156V (full load) / 100V (50% load or less, derates linearly) |
High voltage transfer to battery power (setpoint) | 280V (full load) / 300V (90% load or less) |
SPECIAL FEATURES | |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
High availability UPS features | Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module; Hot swappable batteries |
Green & high efficiency features | High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); CE; Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances) |
UPS Certification details | IEC 61000-4-5 1995 B Surge Immunity |
WARRANTY | |
Product Warranty Period (Worldwide) | 2-year limited warranty |