Done shopping? You can create a PDF of your cart for later or for your purchasing dept! Details at checkout.
Hear What Our Customers Are Saying
-
20+ Years Experience Helping IT Heroes
Take advantage of 20+ years of expertise from a partner with available resources for large deployments, multi-site projects, and complex IT initiatives. We have the team to get the job done. -
Free Solution Design With White Glove Engineers
Solutions architects and project engineers will help you envision a successful outcome and give you personalized recommendations based on your unique needs. Free. Apply today. -
Configuration & Installation Services
Let us take care of configuring and installing your equipment so you can get back to business. Available nationwide. Apply today. -
Equipment Trade-In Program
Refreshing old hardware? Let us coordinate the recycling or destruction in an environmentally friendly and safe manner. As a bonus, working with us gives you access to specific trade-in discounts towards your network refresh. Apply today. -
Exclusive Incentives, Special Pricing, & Financing
After helping you build and validate your solution, we’ll include any applicable discounts, financing, and incentives applied to your project to guarantee you get the most value out of your IT investments through Hummingbird Networks. Apply today.
750VA UPS Smart Online Rack/Tower PureSine 6 outlet
Key Features
- SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications
- True online, double-conversion UPS provides perfectly regulated sine wave output within 2% of 100/110/120V (user selectable) under all usage conditions
- Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
- Removes harmonic distortion, fast electrical impulses, frequency variations and other hard-to-solve power problems not addressed by other UPS types
- Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 100/110/120V (+/-2%) values
- Standard internal battery set offers 11 min. runtime at half load (300W) and 6 min. at full load (600W)
- Extended runtime available with optional BP24V15RT2U (limit 1), BP24V28-2U (limit 1), BP24V70-3U (multi-pack compatible) and BP24V36-2US (multi-pack compatible) external battery packs
- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 13.5 inches
- Ships with all mounting accessories for 4-post rackmount installation
- Optional 2POSTRMKITWM enables 2-post rackmount or wallmount installation
- Optional 2-9USTAND accessory enables small-footprint upright tower placement
- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
- Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot
- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
- UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter sutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints
- Built-in Emergency Power Off (EPO) interface with cable
- NEMA 5-15P input plug/NEMA 5-15R output receptacles
- Integrated 2-bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices (each load bank consists of a single outlet)
- Front panel LEDs offer current monitoring and battery charge level information
- UPS ships fully assembled in full compliance with DOT regulations; no time-consuming connection of internal batteries by user required
- Single-line tel/DSL or network Ethernet line surge suppression
- $250,000 Ultimate Lifetime Insurance
Package Includes
- SU750RTXL2U Online Double-Conversion UPS System
- PowerAlert Software and cabling
- Mounting hardware for 4-post rack enclosures
- Instruction manual
OUTPUT | |
Output Volt Amp Capacity (VA) | 750 |
Output Watt Capacity (watts) | 600 |
Output power factor | 0.8 |
Crest Factor | 3:01 |
Nominal Output Voltage(s) Supported | 100V; 110V; 120V |
Nominal Voltage details | 120V default |
Frequency compatibility | 50 / 60 Hz |
Frequency compatibility details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
Output voltage regulation (line mode) | +/- 2% |
Output voltage regulation (Battery mode) | +/- 2% |
Built-in UPS output receptacles | 6 5-15R outlet(s) |
Built-in controllable switched load banks | Two switchable single-outlet 5-15R load banks |
Output AC waveform (AC mode) | Sine wave |
Output AC waveform (battery mode) | Pure Sine wave |
INPUT | |
Rated input current (at maximum load) | 8.6A |
Nominal Input Voltage(s) Supported | 100V AC; 110V AC; 120V AC |
UPS input connection type | 5-15P |
Input circuit breaker | 15A |
UPS Input cord length (ft.) | 6 |
UPS Input cord length (m) | 1.8 |
Recommended Electrical Service | 15A 120V |
Phase | Single-Phase |
BATTERY | |
Full load runtime (minutes) | 4 min. (600w) |
Half load runtime (minutes) | 11 min. (300w) |
Expandable battery runtime | Extended runtime supported via optional external battery packs |
External battery pack compatibility | BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible); BP24V36-2US (multi-pack compatible) |
DC system voltage (VDC) | 24 |
Battery recharge rate (included batteries) | Less than 6 hours from 10% to 80% |
Replacement battery cartridge (internal UPS battery replacement) | RBC92-2U |
Battery Access | Front panel battery access door |
Battery replacement description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION | |
Voltage regulation description | Online, double-conversion power conditioning |
Overvoltage correction | 2% output voltage regulation during overvoltages to 150 |
Undervoltage correction | 2% output voltage regulation during undervoltages to 80 |
Severe undervoltage correction | 2% output voltage regulation during undervoltages to 65 (under 70% load only) |
LEDS ALARMS & SWITCHES | |
LED Indicators | 14 LEDs indicate line power, online mode, bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats |
Alarms | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
SURGE / NOISE SUPPRESSION | |
UPS AC suppression joule rating | 480 |
UPS AC suppression response time | Instantaneous |
UPS Dataline suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
EMI / RFI AC noise suppression | Yes |
PHYSICAL | |
Installation form factors supported with optional accessories | 2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) |
Primary form factor | Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 3.5 x 17.5 x 13.5 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 8.9 x 44.4 x 34.3 |
Rack Height | 2U |
Secondary form factor | Tower (requires 2-9USTAND) |
UPS / Power Module weight (lbs) | 29 |
UPS / Power Module weight (kg) | 13.2 |
UPS Shipping dimensions (height x width x depth / inches) | 9.5 x 20 x 24 |
UPS Shipping dimensions (height x width x depth / cm) | 24.1 x 50.8 x 61 |
Shipping weight (lbs) | 41 |
Shipping weight (kg) | 18.6 |
Cooling method | Fan |
UPS housing material | Steel |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC mode BTU / hr. (full load) | 304.8 |
Battery mode BTU / hr. (full load) | 332.1 |
AC mode efficiency rating (100% load) | 87% |
COMMUNICATIONS | |
Communications interface | USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface |
Network monitoring port description | Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications |
PowerAlert software | Included |
Communications cable | USB and DB9 cabling included |
WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER | |
Transfer time | No transfer time (0 ms.) in online, double-conversion mode |
Low voltage transfer to battery power (setpoint) | 80V (100% load), 65V ( <70% load) |
High voltage transfer to battery power (setpoint) | 150 |
SPECIAL FEATURES | |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
High availability UPS features | Automatic inverter bypass; Hot swappable batteries |
Green & high efficiency features | Individually controllable load banks |
CERTIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI) |
WARRANTY | |
Product Warranty Period (Worldwide) | 2-year limited warranty |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $250,000 Ultimate Lifetime Insurance |